ANSI/IES RP-6-20 Requirements
Class I | Class II | Class III | Class IV | ||
---|---|---|---|---|---|
Horizontal illuminance | Em fc | 150 | 100 | 75 | 50 |
Emax/Emin | 1.5 | 1.7 | 2.5 | 3.0 |
EN12193 Requirements
Class I | Class II | Class III | |||
---|---|---|---|---|---|
Horizontal illuminance | Em lx | 750 | 500 | 300 | |
Emin/Emax | 0.7 | 0.7 | 0.7 |
The angular size, speed and luminance of its background and the luminance of the surroundings determines the visibility
of moving objects directly. A high standard of lighting is required for ice rink, because the small, black and fast-moving
puck has to be made to contrast against the ice rink so that the spectators and players can see it. This is especially true
where there is a large distance between the ice and the spectators, such as in arenas or halls.
There should be no strong light that could distract from the games because ice acts as a good diffuse reflector. Good
lighting uniformity is also very important for seeing the puck.
ANSI/IES RP-6-20 Requirements
Class I | Class II | Class III | Class IV | ||
---|---|---|---|---|---|
Horizontal illuminance | Em fc | 150 | 100 | 75 | 50 |
Emax/Emin | 1.5 | 1.7 | 2.5 | 3.0 |
EN12193 Requirements
Class I | Class II | Class III | |||
---|---|---|---|---|---|
Horizontal illuminance | Em lx | 750 | 500 | 300 | |
Emin/Emax | 0.7 | 0.7 | 0.7 |
Poles | 5 lines at 30ft |
Floodlight | 30 x Model B 960W |
Floodlight Type | 30 x BBD960-T60D-50K-3535F |
System Power | 28.8KW |
Eh Ave | >150 fc |
Emax/Emin | <1.39 |
GR Max | 13 |
Poles | 3 lines at 30ft |
Floodlight | 18 x Model B 960W |
Floodlight Type | 18 x BBD960-T60D-50K-3535F |
System Power | 17.28KW |
Eh Ave | >100 fc |
Emax/Emin | <1.37 |
GR Max | 17 |
Poles | 3 lines at 30ft |
Floodlight | 15 x Model B 960W |
Floodlight Type | 15 x BBD960-T60D-50K-3535F |
System Power | 14.4KW |
Eh Ave | >75 fc |
Emax/Emin | <1.9 |
GR Max | 20 |
Poles | 3 lines at 30ft |
Floodlight | 12 x Model B 720W |
Floodlight Type | 12 x BBD720-T60D-50K-3535F |
System Power | 8.64KW |
Eh Ave | >50 fc |
Emax/Emin | <1.9 |
GR Max | 23 |
Poles | 3 lines at 10m |
Floodlight | 18 x Model A 960W |
Floodlight Type | 18 x ABD960-T4SB-50K-3535F |
System Power | 17.28KW |
Eh Ave | >750 lux |
Emax/Emin | >0.7 |
GR Max | 34 |
Poles | 2 lines at 10m |
Floodlight | 12 x Model A 960W |
Floodlight Type | 12 x ABD960-T4SB-50K-3535F |
System Power | 11.52KW |
Eh Ave | >500 lux |
Emax/Emin | >0.7 |
GR Max | 33 |
Poles | 2 lines at 10m |
Floodlight | 10 x Model A 720W |
Floodlight Type | 10 x ABD720-T4SB-50K-3535F |
System Power | 7.2KW |
Eh Ave | >300 lux |
Emax/Emin | >0.7 |
GR Max | 33 |